Page 119 - ProStar Product Guide
P. 119

™
          ProStar  Gas-Shielded Wire



          ProStar FC-71LF Wire


          SPECIFICATION
          E71T-1, E71T-1M, E71T-9, E71T-9M per AWS A5.20,
          ASME SFA 5.20, E491T-9-H8, E491T-9M-H8 per
          CSA W48-01

            Wire Dia  Package            Part No.
            0.045"    33 lb (15 kg) spool   PRSS247112-729
                      44 lb (20 kg) spool   PRSS247112-744
                      60 lb (27 kg) coil  PRSS247112-702
            0.052"    33 lb (15 kg) spool  PRSS247115-729
            1/16"     33 lb (15 kg) spool   PRSS247119-729
                      60 lb (27 kg) coil  PRSS247119-702

          CHARACTERISTICS
          •  Low fumes and low spatter
          •  Easy slag removal
          •  Very good out-of-position capabilities

          ProStar FC-71LF wire is a flux-cored wire designed
          for general purpose fabrication, welding in all positions.
          It can be used with either 100% CO 2 or 75% Ar/25%                                                           FILLER METALS
          CO 2 shielding gas, offering a spray-type transfer of weld
          metal. ProStar FC-71LF wire provides good impact
          strength at low temperatures. It also has low fume and
          spatter levels and the slag is easy to remove.

          Shielding Gas                 Welding  Positions
          100% CO2 or 75% Ar/25% CO2    All  positions

          Typical Mechanical Properties*
          Tensile Strength              87,700 psi (605 MPa)
          Yield Strength                79,100 psi (546 MPa)
          Elongation in 2"              28%
          CVN at 0 °F (-18 °C)          70 ft/lb (95 Joules)
          CVN at -20 °F (-29 °C)        51 ft/lb (69 Joules)

          Typical Undiluted Weld Metal Chemistry
          Carbon (C) 0.021
          Manganese (Mn) 1.30
                                                               * The data contained herein is based on testing performed under standard
          Silicon (Si) 0.69                                    laboratory conditions. In normal practice, the results obtained may vary depending
          Phosphorus (P) 0.015                                 upon welding parameters, weld metal cooling rate, and the base plate being
                                                               joined. The user should always test the electrode prior to its application.
          Sulphur (S) 0.011








                          1-800 225 8247        www.praxairwelding.com                                      C19
   114   115   116   117   118   119   120   121   122   123   124