What is the Material Compatibility Chart for Plastic?

Key to Materials Compatibility

SSatisfactory for use with the intended gas.
CConditional. May be incompatible under some circumstances or conditions. Contact your Linde representative for additional information.
UUnsatisfactory for use with the intended gas.
IInsufficient data available to determine compatibility with the intended gas.
OAll nonmetallic, even those considered compatible, may be ignitable in oxygen enriched environments or in other oxidizing gases. Successful use depends upon oxygen purity, pressure, temperature, cleanliness and elimination of ignition mechanisms. Please contact your Linde Representative for additional information.

 

Plastics

Common NameChemical FormulaKel-F®Teflon®Tefzel®Kynar®PVCPolycarbonate
Acetylene C2H2SSSSII
Air--SSSSSS
AmmoniaNH3SSSUII
ArgonArSSSSSS
Arsine AsH3SSSSSI
Boron Trichloride BCl3SSSSSI
Boron TrifluorideBF3SSSSSI
1,3-Butadiene C4H6SSSSSU
Butane C4H10SSSSSU
1-Butene C4H8SSSSSU
Carbon DioxideCO2SSSSSU
Carbon MonoxideCOSSSSSS
ChlorineCl2SSSSUU
DeuteriumD2SCSSSI
Diborane B2H6SSSSSI
Dichlorosilane H2SiCl2SSSSII
Disilane Si2H6SSSSSU
Ethane C2H6SSSSSI
Ethylene C2H4SSSSII
Halocarbon 14CF4ISISII
Halocarbon 22 CHClF2SCSSUU
Halocarbon 23 CHF3SSISII
Halocarbon 116 C2F6SSSSUU
Halocarbon 134A CH2FCF3IIIIII
Halocarbon 218 C3F8SSSIII
HeliumHeSSSSSS
HydrogenH2SiCl2SSSSSS
Hydrogen BromideHBrISISII
Hydrogen ChlorideHClSSSSSU
Hydrogen SulfideH2SiCl2SSSSUS
Isobutane C4H10 SSSSSU
IsobutyleneC4H8 SSSSSU
KryptonKr SSSSSS
Medifume™ Mixture -SSIIUU
MethaneCH4 SSSSSI
Methyl Chloride CH3Cl SSSSII
NeonNeSSSSSS
Nitric OxideNOSSSSSS
NitrogenN2SSSSSS
Nitrogen Dioxide NO2SSSUUI
Nitrogen Trifluoride NF3CCICII
Nitrous Oxide N2OOOCOOI
OxygenO2OOOOOC
Oxyfume® Mixture-SSIIUU
Pentane C5H12SSSSSS
Phosphine PH3SSSSII
Propane C3H8 SSSSSU
Propylene C3H6 SSSSSU
Silane SiH4 SSSSSI
Silicon Tetrachloride SiCl4 SSISUI
Sulfur Dioxide SO2 SSSSSI
Sulfur Hexafluoride SF6 SSSSSI
Trichlorosilane HSiCl3 SSIIUI
Tungsten Hexafluoride WF6 ICCCCI
XenonXe SSSSSS

Note: These charts have been prepared for use with dry (anhydrous) gases at normal operating temperature of 70 °F (21 °C). Information may vary if different operating conditions exist. Systems and equipment used in oxidizer gas service (e.g., Oxygen or Nitrous Oxide) must be cleaned for oxygen service.