Page 21 - ProStar Product Guide
P. 21

™
          ProStar  Gas Hose Repair Kit



          Everything You Need for Quick Repairs


          Kit includes nuts, nipples, couplers, splicer, crimping tool and ferrules.
          Fast, easy, concave crimp ensures strong connections. Convenient plastic
          case is durable, and includes a full-color label and description chart.


            Part No.                         Description                                                               GAS EQUIPMENT
                        C-5 crimp tool for 1/4” (6.4 mm),   B-size fittings only, 9/16”
            PRS27110
                        ID hose                     (14.3 mm) - 18
                        C-5 crimp tool for 3/16” (4.8 mm),   A-size, 3/8” (9.5 mm) - 24) or
            PRS27111
                        1/4” (6.4 mm) ID hose       B-size, 9/16” (14.3 mm) - 18)


          RECOMMENDED SAFETY PRACTICES
          The Compressed Gas Association (CGA) recommends the exclusive
          use of Grade T hose because of its gas compatibility, oil resistance and
          flame resistance. Exclusive use of Grade T hose eliminates the incorrect
          application of other grades of hose. Refer to CGA document SB-11-2004
                                                                                WARNING:
          for delivery pressure.
                                                                                Use of certain fuel gases may
          REDUCE POTENTIAL FLASHBACKS                                           damage welding hose and lead to
                                                                                fires and explosions.
          When the torch will not be used for periods in excess of thirty minutes,
                                                                                •  Use only Grade T hose with
          first shut off the gas at the torch, and last at the regulator or supply source   propane, propylene or any similar
          to limit gas permeation through the hose wall. Shutting off the fuel gas   fuel gas. Do not exceed 40 psi
          at the regulator or supply source first can cause a flashback, damaging   delivery pressure.
          the hose and/or regulator. Adequate ventilation must be provided in   •  Use Grade R, RM or T hose with
                                                                                  acetylene. Do not exceed 15 psi
          confined areas where fuel gas is used, in order to prevent accumulation   delivery pressure.
          or concentration of gas that could be explosive or harmful to personnel.



                               Temperature Rating           Max WP
                                                                                Caution: Care should be taken to
            Hose Type      ° Fahrenheit  ° Celsius     psi         Mpa
                                                                                avoid gouging, dragging, abrading,
            Grade R,       -40° to 120°  -40° to 48°   200         1.38         or otherwise damaging the hose
            RM Twin, Single                                                     cover, which may also lead to
                                                                                premature hose failure. Do not
            Grade T Twin   -20° to 120°  -28° to 48°   200         1.38
                                                                                attempt to repair or re-couple hose
            Grade T Twin   -20° to 120°  -28° to 48°   200         1.38         assemblies; replace all assemblies
            Grade T Single  -50° to 120°  -45° to 48°  200         1.38         that show signs of age or abuse.
















                          1-800 225 8247      www.praxairwelding.com                                        A17
   16   17   18   19   20   21   22   23   24   25   26