Page 21 - ProStar Product Guide
P. 21
™
ProStar Gas Hose Repair Kit
Everything You Need for Quick Repairs
Kit includes nuts, nipples, couplers, splicer, crimping tool and ferrules.
Fast, easy, concave crimp ensures strong connections. Convenient plastic
case is durable, and includes a full-color label and description chart.
Part No. Description GAS EQUIPMENT
C-5 crimp tool for 1/4” (6.4 mm), B-size fittings only, 9/16”
PRS27110
ID hose (14.3 mm) - 18
C-5 crimp tool for 3/16” (4.8 mm), A-size, 3/8” (9.5 mm) - 24) or
PRS27111
1/4” (6.4 mm) ID hose B-size, 9/16” (14.3 mm) - 18)
RECOMMENDED SAFETY PRACTICES
The Compressed Gas Association (CGA) recommends the exclusive
use of Grade T hose because of its gas compatibility, oil resistance and
flame resistance. Exclusive use of Grade T hose eliminates the incorrect
application of other grades of hose. Refer to CGA document SB-11-2004
WARNING:
for delivery pressure.
Use of certain fuel gases may
REDUCE POTENTIAL FLASHBACKS damage welding hose and lead to
fires and explosions.
When the torch will not be used for periods in excess of thirty minutes,
• Use only Grade T hose with
first shut off the gas at the torch, and last at the regulator or supply source propane, propylene or any similar
to limit gas permeation through the hose wall. Shutting off the fuel gas fuel gas. Do not exceed 40 psi
at the regulator or supply source first can cause a flashback, damaging delivery pressure.
the hose and/or regulator. Adequate ventilation must be provided in • Use Grade R, RM or T hose with
acetylene. Do not exceed 15 psi
confined areas where fuel gas is used, in order to prevent accumulation delivery pressure.
or concentration of gas that could be explosive or harmful to personnel.
Temperature Rating Max WP
Caution: Care should be taken to
Hose Type ° Fahrenheit ° Celsius psi Mpa
avoid gouging, dragging, abrading,
Grade R, -40° to 120° -40° to 48° 200 1.38 or otherwise damaging the hose
RM Twin, Single cover, which may also lead to
premature hose failure. Do not
Grade T Twin -20° to 120° -28° to 48° 200 1.38
attempt to repair or re-couple hose
Grade T Twin -20° to 120° -28° to 48° 200 1.38 assemblies; replace all assemblies
Grade T Single -50° to 120° -45° to 48° 200 1.38 that show signs of age or abuse.
1-800 225 8247 www.praxairwelding.com A17