Page 73 - Medical Gases and Equipment Catalog
P. 73

Medical Gases and Equipment Catalog

Threaded Outlet Type Valves With Handwheels

Threaded outlet valves for large cylinders are separated into four           Where size permits, it is recommended that valves, nuts and
basic divisions – Internal Thread (INT), External Thread (EXT),              nipples be marked with the appropriate CGA number. Left Hand
Right Hand Thread (RH), and Left Hand Thread (LH). Further                   Threads (LH) are identified by a V-groove in the hexagonal nut.
separation is made within each division by varying the diameter              Each outlet provides for screw threads which do not seal, but
of the threads, and the size and shape of seats and nipples for              merely hold the nipple against a seat in the valve outlet or against
any given thread size.                                                       a washer.

CGA CONNECTION NO. 280                                                       CGA CONNECTION NO. 320
.745-14NGO-RH-EXT                                                            .825-14NGO-RH-EXT (Flat Nipple)
Carbon Dioxide-Oxygen Mixtures                                               Carbon Dioxide
OO(CxxOyy2ggee<nno--NNr ii=ttrroo7ug.0se%nO)MxidixetuMreixstu(Ore2s> 23.5%)  CGA CONNECTION NO. 346
(HNe2lOium47-.O5xtyog5en2.M5%ix)tures                                        .825-14NGO-RH-EXT
(He < or = 80% )                                                             (Large Round Nipple)
Xenon-Oxygen Mixtures                                                        Air
(Xe < or = 80% )
CGA CONNECTION NO. 326
(Formerly 1320)
.825-14NGO-RH-EXT
(Small Round Nipple)
Nitrous Oxide

CGA CONNECTION NO. 500                                                       CGA CONNECTION NO. 540
.885-14NGO-RH-INT (Bullet Nipple)                                            .903-14NGO-RH-EXT
Carbon Dioxide-Oxygen Mixtures                                               Oxygen
(CO2> 7.0%)
Helium-Oxygen Mixtures
(He > 80.0%)
Lung Diffusion Mixtures
Nonflammable, Non-corrosive Diagnos-
tic and Medically Related Gas Mixtures
CGA CONNECTION NO. 580
.965-14NGO-RH-INT
Helium
Nitrogen
Xenon