Oxygen U.S.P. Cryogenic Liquid

Odorless, highly oxidizing, light blue cryogenic liquid

Cryogenic Containers                                                     Major Hazards: Fire and Cryogenic Burns
                                                                                Toxicity: Nontoxic
70 in.
                                                                          Fire Potential: Highly Oxidizing
60 in.                                                                Boiling Point (°F): -297.4
                                                                     Molecular Weight: 32.00
50 in.                                                                 Specific Gravity: 1.14
                                                              Critical Temperature (°F): -181.5
40 in.                                                          Critical Pressure (psia): 731.4
                                                                Specific Volume (cf/lb): 12.1
30 in.
                                                                                 UN No.: 1073
20 in.                                                                             DOT Designation
                                                                                  Name: Oxygen, Refrigerated Liquid
10 in.                                                                             Label: Yellow Oxidizer

 0 in.            HP-160   LS-160  CD-170  LS-180 XL-230/240     Hazard Classification: 2.2
                  (GP-55)   471      471    471 472
Container HP-180            271      271    271 272
Size (GP-55)        471
Size 471          271/274
Code 271/274

PURITY SPECIFICATIONS      CO2 < 300ppm    MSDS
Purity : Oxygen > 99.0%    CO < 10ppm      P-4637
Odor: None

                               CYLINDER SPECIFICATIONS                              Equipment Recommendations
                      Cylinder Nominal Pressure
Ordering Number                                                 CGA Connection      Regulator
OX MLC160-230           Size Contents (psig) @ 70°F           GAS 540 / LIQUID 440  WESM1-540-P
OX MLC160-22                                                  GAS 540 / LIQUID 440  N/A
OX MLC180-230         160 L 4580 cu ft     230                GAS 540 / LIQUID 440  WESM1-540-P  WESM1-540-PG
OX MLC180-22                                                  GAS 540 / LIQUID 440  N/A          WESM1-540-PG
OX ML230-230          160 L 4580 cu ft     22                 GAS 540 / LIQUID 440  WESM1-540-P  WESM1-540-PG
OX ML230-22                                                   GAS 540 / LIQUID 440  N/A
                      180 L 4640 cu ft     230

                      180 L 4640 cu ft     22

                      230 L 5930 cu ft     230

                      230 L 5930 cu ft     22

        Color Code :                       Shoulder Color: N /A                     Body Color : N /A

Medical Applications
Used in first-aid treatment of emergencies such as suffocation and heart attacks; in the treatment of patients with respiratory disor-
ders; in anesthesia; in hyperbaric oxygen chambers for the treatment of carbon monoxide poisoning and gas gangrene, and for other
specialized oxygen therapies

Praxair, the Flowing Airstream design, Medipure and Grab ’n Go are trademarks or registered trademarks of Praxair Technology, Inc. in the United States and/or other countries.
Other trademarks used herein are property of their respective owners. The information contained herein is offered for use by technically qualified personnel at their discretion
and risk without warranty of any kind. © Copyright 2014, Praxair Technology, Inc. All rights reserved. Praxair Inc., Danbury, CT 06810-5113
   9   10   11   12   13   14   15   16   17   18   19